top of page

Englander Pellet Stove Control Board: Settings and Reset Guide

David Thibodeau

Updated: Jan 9


Englander pellet stoves are renowned for their efficiency and reliability, but understanding their control boards is essential to ensure the best performance. This blog will guide you through resetting and reprogramming your Englander control board and provide an overview of proper settings for various models. Let’s dive in!


Englander control board explained
Englander Control Board

Reset Procedure for Standard Englander Control Boards


If your Englander pellet stove features a side-mounted control board, follow these steps to reset it:


(1) Reboot the Control Board


  • Unplug the power cord from the unit.


  • Plug the power cord back in and, within 5 seconds, simultaneously press and release the three bottom buttons on the touchpad.

    • The control board will display “F-S”, then typically revert to “1-1”.


  • Allow the display to go completely blank before unplugging the unit again.


(2) Reprogram the Profile


  • Plug the power cord back in.


  • Quickly press the Blower Speed UP/DOWN arrows simultaneously and release.


    • The default profile will appear on the Heat Range display for approximately 5 seconds. (This may be displayed as a letter, such as "A," or a number, such as "3.")


  • Use the Heat Range UP or DOWN arrow while the profile is displayed to select the correct profile for your stove model.


    • Once set, the control board will return to its Heat Range and Blower Speed settings.


(3) Adjust Trim Settings


  • Press each button in turn to check the lower three trim settings. The settings will appear in the Blower Speed display.


  • Adjust the settings as follows:

    • Use the blower speed controls for boards with letter profiles (A, B, C, D).

    • For boards with number profiles (1-9), press BOTH UP arrows together to increase or BOTH DOWN arrows to decrease.

    • Refer to the chart below for proper presets for each model.


 

Englander Control Boards Profiles and Trim Settings


Models Made 2019 & Up

(England Stove Works)

Current Englander models control board settings
Profile & Trim Settings

Models Made Before 2019

Englander discontinued control board settings
Profile & Trim Settings

 

Bottom button function


bottom buttons on Englander

Low Fuel Feed

  • Run time on the feed auger motor


Low Burn Air

  • Speed of exhaust fan


Air On Temp

  • Temperature functions always 1



 

Troubleshooting Tips


Unresponsive Controls

  • If the control board does not respond to the reset procedures, verify the power supply and check the fuse to see if it is good.


Incorrect Heat Output

  • Ensure the profile and bottom settings match your stove’s specifications.


Fluctuating Performance

  • Double-check trim settings and recalibrate if necessary.


 

Why do Proper Settings Matter?


Accurate Englander control board settings ensure efficient fuel use, consistent heat output, and prolonged pellet stove life. Improper configurations can reduce performance and result in excessive pellet consumption and unnecessary wear and tear.


 

Englander Pellet Stove Service

Servicing Rhode Island and surrounding mass towns


Northeast Pellet Stove Logo

Contact Northeast Pellet Stoves or visit our website for expert guidance. Let us help you keep your pellet stove running like new!